CZ02 -EMC Radiation Emission Test Summary- Summary
Huaxun / Shenzhen HX Detect Certification Co., Ltd.
EMC Test Report No.: HX2006095500
1. CZ02 -EMC Radiation emission test summary-Testing Facility Credibility
Shenzhen HX Detect Certification Co., Ltd. is a professional electromagnetic compatibility (EMC) and safety testing laboratory equipped with certified EMI receivers, calibrated antennas, ESD systems, and fully anechoic chambers.
The laboratory performs CE, FCC, and international compliance testing in accordance with EN and IEC standards.
2. Description of Tests Performed
Tested Device: OH-FEEL Hydroxyl Air Protection System (Model CZ01, representative of the CZ series)
Applied Standards:
- EN 55014-1:2017 — Radiated and conducted emissions
- EN 55014-2:2015 — Immunity to electrostatic discharge (ESD) and RF fields
3. CZ02 -EMC Radiation emission test summary – Key Results
Radiated Emissions (pages 10–11): All measured values from 30 to 1000 MHz were below CE limit requirements.
Electrostatic Discharge (ESD) Test (page 14):
- ±8 kV air discharge — PASS
- ±4 kV contact discharge — PASS
Radiated RF Immunity Test (page 17): 80–1000 MHz at 3 V/m, AM 1 kHz — PASS for all sides (Criterion A).
4. Certification Details
- Application No.: HX2006095499
- Test Report No.: HX2006095500
- Test Period: June 04–09, 2020
- Issue Date: June 09, 2020
This summary confirms CE EMC compliance under Directive 2014/30/EU for OH-FEEL CZ Series systems.
This summary is provided for clarity. For full data and detailed methodology, please refer to the original CE EMC compliance test report.