{"id":2982,"date":"2026-01-11T17:07:29","date_gmt":"2026-01-11T17:07:29","guid":{"rendered":"https:\/\/ohfeel.gr\/oh-feel-500f08-perilipsi-analysis-nosokomeiakis-asfaleias-kai-apodosis\/"},"modified":"2026-01-22T08:07:13","modified_gmt":"2026-01-22T08:07:13","slug":"oh-feel-500f08-hospital-efficacy-and-safety","status":"publish","type":"page","link":"https:\/\/ohfeel.gr\/en\/oh-feel-500f08-hospital-efficacy-and-safety\/","title":{"rendered":"OH-Feel 500F08 -Hospital efficacy and safety"},"content":{"rendered":"\t<section class=\"section\" id=\"section_1075470969\" >\n\t\t<div class=\"section-bg fill\"  >\n\t\t\t        \n\t\t\t            \n\t\t\t\t\t\t\n\t<div class=\"is-border\"\n\t\tstyle=\"border-color:rgb(80, 170, 182);border-width:10px 10px 10px 10px;margin:0px 0px 0px 0px;\">\n\t<\/div>\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-1486094018\">\n\n\t<div id=\"col-1572817770\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"text-4015279443\" class=\"text\">\n\t\t\n<div class=\"report-summary\">\n<h2>HOSPITAL ACCREDITATION ANALYSIS SUMMARY<\/h2>\n<p><strong>Guangdong Detection Center of Microbiology (CNAS Accredited Laboratory)<\/strong><\/p>\n<h3>1. Testing Facility Credibility<\/h3>\n<p>The Guangdong Detection Center of Microbiology (GDDCM) is a CNAS-accredited national laboratory specializing in medical disinfection standards, microbiological testing, sterilization performance, and air-quality safety evaluations. It is one of China\u2019s leading recognized authorities for medical grade air disinfection validation and HVAC compliance. This accreditation ensures strict adherence to ISO\/IEC 17025 laboratory competence requirements.<\/p>\n<h3>2. Description of the Tests Performed<\/h3>\n<p>The OH-Feel OH500F08 underwent multiple medical grade evaluations, including:<\/p>\n<ul>\n<li>Ozone concentration assessment \u2014 measured according to GB 28235-2020. Results across repeated sampling averaged 0.006 mg\/m\u00b3 (~3 ppb), confirming extremely low ozone output. (Page 3)<\/li>\n<li>Circulating air volume measurement \u2014 conducted using the GB\/T 14295-2008 Appendix B method. The OH500F08 achieved an average circulating air volume of 477.3 m\u00b3\/h. (Page 4)<\/li>\n<li>UV leakage safety test \u2014 measured at a 30 cm perimeter distance as required by GB 28235-2020. UV radiation leakage was recorded as 0 \u00b5W\/cm\u00b2, meeting the strict requirement of &lt;5 \u00b5W\/cm\u00b2. (Page 4)<\/li>\n<li>Ultraviolet radiation intensity (operational) \u2014 measured for 10 minutes at 1 minute intervals. The sterilization UV lamp maintained a stable average intensity of 175.2 \u00b5W\/cm\u00b2. (Page 5)<\/li>\n<li>Airborne bacteria removal test \u2013 40 m\u00b3 test chamber \u2014 GB test method. Reduction of natural airborne microbes reached: 92.83% after 2 hours; 92.94% after 3 hours. (Page 6)<\/li>\n<\/ul>\n<h3>3. Staphylococcus albus Disinfection Test (Medical-Grade Standard)<\/h3>\n<p>The OH500F08 was tested in a controlled 20 m\u00b3 aerosolized bacterial chamber following the Technical Standard for Disinfection (Ministry of Health P.R. China). This test evaluates professional hospital grade sterilization capability. (Page 7)<\/p>\n<p><strong>Results:<\/strong><\/p>\n<ul>\n<li>1 hour: 99.79% kill rate (Staphylococcus albus)<\/li>\n<li>2 hours: 99.97% kill rate<\/li>\n<li>3 hours: 99.97% kill rate<\/li>\n<\/ul>\n<p>These disinfection levels meet \u2014 and in many cases exceed \u2014 requirements for hospital air sterilization devices.<\/p>\n<h3>4. Summary Statement<\/h3>\n<p>Based on the official medical grade evaluations performed by the CNAS accredited Guangdong Detection Center of Microbiology, the OH-Feel OH500F08 meets the standards for hospital level air disinfection systems. It demonstrates:<\/p>\n<ul>\n<li>Ultra low ozone emission (~3 ppb)<\/li>\n<li>Zero UV leakage<\/li>\n<li>High circulating air volume (477.3 m\u00b3\/h)<\/li>\n<li>Strong UV sterilization output (175.2 \u00b5W\/cm\u00b2)<\/li>\n<li>&gt;99.97% microbial elimination performance<\/li>\n<\/ul>\n<p>This confirms the OH500F08 is suitable for use in medical environments requiring validated air sterilization.<\/p>\n<p><strong>Report No.:<\/strong> 2022FM10597R01E<\/p>\n<p><strong>Test Completion Date:<\/strong> 2022-06-24<\/p>\n<p>This summary is provided for clarity.<\/p>\n<p>Refer to the original test report for full data and methodology.<\/p>\n<\/div>\n\t\t\n<style>\n#text-4015279443 {\n  text-align: left;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1078342902\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<a id=\"btn-2247199564\" href=\"https:\/\/ohfeel.gr\/wp-content\/uploads\/2025\/12\/OH-Feel-500F08-\u2013-Safety-Efficacy-\u2013-Hospital-Environmental-Performance-Evaluation-Ozone-Airflow-UV-Leakage-Microbial-Reduction-Tests-GB-28235-2020-\u2013-Summary-\u2013-2022.pdf.pdf\" target=\"_blank\" rel=\"noopener\" class=\"button primary expand\" >\n                        <span>Download Summary<\/span>            \t<\/a>\n    \n<style>\n#btn-2247199564 {\n  border-radius: 99px!important;\n}\n<\/style>\n\t\n\t<a id=\"btn-1809314243\" href=\"https:\/\/ohfeel.gr\/wp-content\/uploads\/2025\/12\/OH-Feel-500F08-\u2013-Safety-Efficacy-\u2013-Hospital-Environmental-Performance-Evaluation-Ozone-Airflow-UV-Leak-Microbial-Reduction-Tests-GB-28235-2020-\u2013-Guangdong-Microbiology-Institute-\u2013-2022.-pdf.pdf\" target=\"_blank\" rel=\"noopener\" class=\"button primary expand\" >\n                        <span>Download Study<\/span>            \t<\/a>\n    \n<style>\n#btn-1809314243 {\n  border-radius: 99px!important;\n}\n<\/style>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n        \n<style>\n#section_1075470969 {\n  padding-top: 80px;\n  padding-bottom: 80px;\n}\n<\/style>\n\t<\/section>\n    \t\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":5,"featured_media":3317,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-2982","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/ohfeel.gr\/en\/wp-json\/wp\/v2\/pages\/2982","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ohfeel.gr\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ohfeel.gr\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ohfeel.gr\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/ohfeel.gr\/en\/wp-json\/wp\/v2\/comments?post=2982"}],"version-history":[{"count":6,"href":"https:\/\/ohfeel.gr\/en\/wp-json\/wp\/v2\/pages\/2982\/revisions"}],"predecessor-version":[{"id":3019,"href":"https:\/\/ohfeel.gr\/en\/wp-json\/wp\/v2\/pages\/2982\/revisions\/3019"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ohfeel.gr\/en\/wp-json\/wp\/v2\/media\/3317"}],"wp:attachment":[{"href":"https:\/\/ohfeel.gr\/en\/wp-json\/wp\/v2\/media?parent=2982"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}